Komax sludge heat exchanger
Sludge to Water Heat Exchanger & Sludge to Sludge Heat Exchanger utilizing Hi-Pass™ non-plugging static mixer elements
Advantages of Klean-Wall™ Heat Exchanger
– 400% efficiency over standard tube/shell & spiral heat exchangers. Will not clog. Can pass debris up to 50% the diameter of the pipe.
– Eliminates wall buildup of sludge-Efficiency will not degrade over time (High turbulence at boundary walls eliminates fouling and wall build-up).
– Should never require cleaning.
– Improves the digester performance by breaking up and mixing the sludge.
– Available in many piping configurations for easy retro fit.
– If preventive cleaning is desired, the Hi-Pass design allows a clear pathway down the centerline of the tube side to facilitate hydro-rod cleanout.
The integral Hi-Pass™ mixer increases the turbulence of the sludge and eliminates the boundary wall velocity gradient. The turbulent sludge constantly scavenges the wall surface, eliminating fouling of the heat exchanger. The heat exchanger is designed to pass large debris including stringy rope-like debris without plugging. These patented non-clogging mixing elements have proven their reliability in thousands of severe condition sludge dewatering/polymer mixing applications. An added benefit of the Klean-Wall™ heat exchanger is increased bacteriological activity and improved digesting due to the shearing and mixing of the sludge.
DIGESTERS APPLICATION:
Komax Klean-Wall™ heat exchangers can be installed in a circulation loop for heating large digesters. With the additional benefit of increased digester temperature, digester retention time is reduced 50% over conventional Anaerobic Digesters. Contact Komax for more information including current reference sites.
Consistent heat transfer efficiency to save energy is a challenge for municipalities. Heat exchangers were designed to transfer as much energy as possible. However, they are not as efficient as needed.
The Komax heat exchanger increases the heat transfer efficiency multiple times as compared to a conventional tube in a tube heat exchanger.
Heat exchanger efficiency is the ratio of the actual heat transfer. Komax technology can increase heat transfer four-six times more than straight-jacketed pipe heat exchangers and can heat sludge flow rates from 100 gpm to 10,000 gpm. The effectiveness of the heat exchanger is critical and determines the overall efficiency of a plant.
Benefits of Komax Municipal Sludge Heat Exchangers
– Control the temperature of sludge during the digestion process.
– Avoid shutdowns due to blockages.
– 4x to 6x more efficient than straight-jacketed pipe heat exchangers.
– 25% more efficient than spiral heat exchangers without clogging.
– 60% more cost effective than shell and tube or spiral-type heat exchangers.
The Komax Industry Leading Solution
Komax saw the problem and implemented new technology to sludge heat exchangers by removing the internal film coefficient that prevents high heat transfer. Komax utilize the patented non-clogging Hi-pass static mixing elements.
The jacketed heat exchanger transfers heat from one media to another by utilizing hot water or hot sludge.
Case Study The Klean-Wall Heat Exchanger installed at the Southeast Water Reclamation Plant in Lubbock, Texas is part of a recirculation loop with the largest anaerobic digesters in Texas. This heat exchanger has been in service for more than 5 years and has provided consistent heat transfer efficiency resulting in reliable Biosolids output.
The Komax Klean-Wall Heat Exchanger is a significant improvement in heat transfer needed in municipal wastewater applications, particularly municipal sludge and FOG (fat, oil and grease). Heat from outgoing digested sludge is transferred to the cold incoming sludge, promoting resiliency in anaerobic digestion for biosolids output. An added benefit is a reduction in greenhouse gas emissions and the sequestering of carbon.
Reviews